Eyeworld Daily News

2018 ASCRS Washington, D.C. Daily Sunday

EyeWorld Today is the official daily of the ASCRS Symposium & Congress. Each issue provides comprehensive coverage editorial coverage of meeting presentations, events, and breaking news

Issue link: https://daily.eyeworld.org/i/969438

Contents of this Issue

Navigation

Page 4 of 96

COAXIAL OR BIMANUAL? YES. The INTREPID ® Transformer I/A Handpiece is engineered for versatile phaco. A simple twist lets you optimize your approach at every moment of your Centurion ® Vision System procedures. The INTREPID ® Transformer I/A Handpiece Coaxial • Smooth, capsular-friendly tip • Access to cortical material at majority of clock hours • Improved irrigation fl ow 1 Bimanual • Greater access to subincisional cortex • Aspiration from either side • Designed to provide greater controlled lens positioning 1. Alcon Data on File. (April, 2013) CENTURION ® VISION SYSTEM IMPORTANT PRODUCT INFORMATION CAUTION: Federal (USA) law restricts this device to sale by, or on the order of, a physician. As part of a properly maintained surgical environment, it is recommended that a backup IOL Injector be made available in the event the AutoSert ® IOL Injector Handpiece does not perform as expected. INDICATION: The Centurion ® Vision System is indicated for emulsifi cation, separation, irrigation, and aspiration of cataracts, residual cortical material and lens epithelial cells, vitreous aspiration and cutting associated with anterior vitrectomy, bipolar coagulation, and intraocular lens injection. The AutoSert ® IOL Injector Handpiece is intended to deliver qualifi ed AcrySof ® intraocular lenses into the eye following cataract removal. The AutoSert ® IOL Injector Handpiece achieves the functionality of injection of intraocular lenses. The AutoSert ® IOL Injector Handpiece is indicated for use with the AcrySof ® lenses SN6OWF, SN6AD1, SN6AT3 through SN6AT9, as well as approved AcrySof ® lenses that are specifi cally indicated for use with this inserter, as indicated in the approved labeling of those lenses. WARNINGS: Appropriate use of Centurion ® Vision System parameters and accessories is important for successful procedures. Use of low vacuum limits, low fl ow rates, low bottle heights, high power settings, extended power usage, power usage during occlusion conditions (beeping tones), failure to suffi ciently aspirate viscoelastic prior to using power, excessively tight incisions, and combinations of the above actions may result in signifi cant temperature increases at incision site and inside the eye, and lead to severe thermal eye tissue damage. Good clinical practice dictates the testing for adequate irrigation and aspiration fl ow prior to entering the eye. Ensure that tubings are not occluded or pinched during any phase of operation. The consumables used in conjunction with ALCON ® instrument products constitute a complete surgical system. Use of consumables and handpieces other than those manufactured by Alcon may aff ect system performance and create potential hazards. AEs/COMPLICATIONS: Inadvertent actuation of Prime or Tune while a handpiece is in the eye can create a hazardous condition that may result in patient injury. During any ultrasonic procedure, metal particles may result from inadvertent touching of the ultrasonic tip with a second instrument. Another potential source of metal particles resulting from any ultrasonic handpiece may be the result of ultrasonic energy causing micro abrasion of the ultrasonic tip. ATTENTION: Refer to the Directions for Use and Operator's Manual for a complete listing of indications, warnings, cautions and notes. Contact your Alcon representative to see how the INTREPID ® Transformer I/A Handpiece can transform your phaco. © 2017 Novartis 11/17 US-CNT-16-E-5048(1) Advancing CATARACT SURGERY Centurion ® VISION SYSTEM

Articles in this issue

Archives of this issue

view archives of Eyeworld Daily News - 2018 ASCRS Washington, D.C. Daily Sunday